XS
SM
MD
LG
Equipment Information
À¯µµ °áÇÕ ÇöóÁ ºÐ±¤ºÐ¼®±â(Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES))
ÀåºñÁ¤º¸
Equip. Info.
¿¹¾à ¹× ÀÇ·Ú
Reservation
±âº»Á¤º¸
¼³ºñ¹øÈ£
10090189
Àåºñ¸í(ÇѱÛ)
À¯µµ °áÇÕ ÇöóÁ ºÐ±¤ºÐ¼®±â
Àåºñ¸í(¿µ¹®)
Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES)
Á¦ÀÛ»ç
Thermo Scientific
¸ðµ¨¸í
iCAP 6500 DUO
»ó¼¼Á¤º¸
Àåºñ»ç¾ç
- Spectrometer : Echelle Type
- Wavelength range : 166-847nm
- RF source : 27.12MHz solid state, 750-1600Watts output power
- Sample pump : 4-channel(6500Model) 12roller peristaltic. speed 0-125rpm
- Plasma gas : flexed 12L/min, argon
- Nebulizer gas : Mass Folw Control
Ȱ¿ëºÐ¾ß
°­ Áß ¿ø¼Òµé¿¡ ´ëÇÑ Á¤¼º, Á¤·®
Àåºñ¿î¿µÀηÂ
¼³Ä¡Àå¼Ò
ö°­´ëÇпø 176È£
¼Ò¼Ó
ö°­´ëÇпø
¼º¸í
¼­¿ë±¹
ÀüÈ­
054-279-9072
À̸ÞÀÏ
ctboy92@postech.ac.kr
µ¿ÀÏ/À¯»çÀåºñÁ¤º¸
Àåºñ¸í
(GLOCAL)¾×üũ·Î¸¶Åä±×·¡ÇÇ »ï´Ü»çÁß±ØÀÚ Áú·®ºÐ¼®±â(Liquid Chromatography-Triple Quadrupole Mass Spectrometry)
Á¦ÀÛ»ç
Waters
¸ðµ¨¸í
Xevo Absolute system
¼³Ä¡Àå¼Ò
3308È£
Àåºñ¸í
Àü°è¹æ»çÇü ÁÖ»çÀüÀÚÇö¹Ì°æ(Field Emission Scanning Electron Microscope (FE-SEM))
Á¦ÀÛ»ç
Carl Zeiss
¸ðµ¨¸í
GeminiSEM 500
¼³Ä¡Àå¼Ò
RIST1µ¿ 1153È£
Àåºñ¸í
Àü°è¹æ»çÇü ÁÖ»çÀüÀÚÇö¹Ì°æ(Field Emission Scanning Electron Microscope (FE-SEM))
Á¦ÀÛ»ç
Carl Zeiss
¸ðµ¨¸í
AURIGA
¼³Ä¡Àå¼Ò
RIST1µ¿ 1163È£
Àåºñ¸í
Àü°è¹æÃâ Çö¹Ì°æ(Field Emission Electron Microscope)
Á¦ÀÛ»ç
JEOL
¸ðµ¨¸í
JEM-2100F
¼³Ä¡Àå¼Ò
RIST1µ¿ 1188È£
Àåºñ¸í
Àü°è¹æ»çÇü ÁÖ»çÀüÀÚÇö¹Ì°æ(Field Emission Scanning Electron Microscope (FE-SEM))
Á¦ÀÛ»ç
JEOL
¸ðµ¨¸í
JSM-7600F
¼³Ä¡Àå¼Ò
RIST1µ¿ 1192È£
Àåºñ¸í
±Û·Î¿ì ¹æÀü Áú·®ºÐ¼®±â(Glow Discharge Mass Spectrometry (GD-MS))
Á¦ÀÛ»ç
Thermo Scientific
¸ðµ¨¸í
ELEMENT GD
¼³Ä¡Àå¼Ò
RIST1µ¿ 1302È£
Àåºñ¸í
°íºÐÇØ´É À¯µµ °áÇÕ ÇöóÁ Áú·®ºÐ¼®±â(High Resolution Inductively Coupled Plasma Mass Spectrometer (HR-ICP-MS))
Á¦ÀÛ»ç
Thermo Scientific
¸ðµ¨¸í
ELEMENT XR
¼³Ä¡Àå¼Ò
RIST1µ¿ 1304È£
Àåºñ¸í
»ïÁß »ç±ØÀÚ À¯µµ °áÇÕ ÇöóÁ Áú·®ºÐ¼®±â(Triple Quadrupole Inductively Coupled Plasma Mass Spectrometer (TQ-ICP-MS))
Á¦ÀÛ»ç
Thermo Scientific
¸ðµ¨¸í
iCAP TQ
¼³Ä¡Àå¼Ò
RIST1µ¿ 1306È£
Àåºñ¸í
À¯µµ °áÇÕ ÇöóÁ ºÐ±¤ºÐ¼®±â(Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES))
Á¦ÀÛ»ç
AMETEK
¸ðµ¨¸í
Spectro Arcos
¼³Ä¡Àå¼Ò
RIST1µ¿ 1309È£
Àåºñ¸í
À¯µµ °áÇÕ ÇöóÁ ºÐ±¤ºÐ¼®±â(Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES))
Á¦ÀÛ»ç
PerkinElmer
¸ðµ¨¸í
Optima 8300
¼³Ä¡Àå¼Ò
RIST1µ¿ 1311È£
Àåºñ¸í
À¯µµ °áÇÕ ÇöóÁ ºÐ±¤ºÐ¼®±â(Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES))
Á¦ÀÛ»ç
Thermo Scientific
¸ðµ¨¸í
iCAP 7000 Series
¼³Ä¡Àå¼Ò
RIST1µ¿ 1311È£
Àåºñ¸í
À¯µµ °áÇÕ ÇöóÁ ºÐ±¤ºÐ¼®±â(Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES))
Á¦ÀÛ»ç
AMETEK
¸ðµ¨¸í
Spectro Arcos
¼³Ä¡Àå¼Ò
RIST1µ¿ 1311È£
Àåºñ¸í
ÀÌÂ÷ÀÌ¿ÂÁú·®ºÐ¼®±â(Secondary Ion Mass Spectrometry (SIMS))
Á¦ÀÛ»ç
CAMECA Instruments
¸ðµ¨¸í
IMS 6F
¼³Ä¡Àå¼Ò
³ª³ëÀ¶ÇÕ±â¼ú¿ø 105È£
Àåºñ¸í
Àü°è¹æ»çÇü ÁÖ»çÀüÀÚÇö¹Ì°æ(Field Emission Scanning Electron Microscope (FE-SEM))
Á¦ÀÛ»ç
LEO Elektronrnmikroskopie GmbH
¸ðµ¨¸í
FE-SEM
¼³Ä¡Àå¼Ò
³ª³ëÀ¶ÇÕ±â¼ú¿ø Ŭ¸°·ëµ¿ 2Ãþ Ŭ¸°·ë
Àåºñ¸í
À¯µµ°áÇÕ ÇöóÁ ½Ä°¢ ÀåÄ¡(Inductively Coupled Plasma (ICP) Etcher)
Á¦ÀÛ»ç
(ÁÖ)µð¿¥¿¡½º
¸ðµ¨¸í
ICP Etcher
¼³Ä¡Àå¼Ò
³ª³ëÀ¶ÇÕ±â¼ú¿ø Ŭ¸°·ëµ¿ 2Ãþ Ŭ¸°·ë
Àåºñ¸í
Àü°è¹æ»çÇü Åõ°úÀüÀÚ Çö¹Ì°æ(Field Emission Transmission Electron Microscope (FE-TEM))
Á¦ÀÛ»ç
JEOL
¸ðµ¨¸í
JEM-2100 (HR)
¼³Ä¡Àå¼Ò
Á¦1°øÇаü 105È£
Àåºñ¸í
°Ç½Ä½Ä°¢ÀåÄ¡(Inductively Coupled Plasma (ICP) Etcher)
Á¦ÀÛ»ç
Korea Vacuum Tech
¸ðµ¨¸í
KVICP-T406530
¼³Ä¡Àå¼Ò
Á¦1°øÇаü 210È£
Àåºñ¸í
Àü°è¹æ»çÇü ÁÖ»çÀüÀÚ Çö¹Ì°æ(Field Emission Scanning Electron Microscope (FE-SEM))
Á¦ÀÛ»ç
PHILIPS ELECTRON OPTICS B.V.
¸ðµ¨¸í
XL30S FEG
¼³Ä¡Àå¼Ò
Á¦1°øÇаü 306-1È£
Àåºñ¸í
À¯µµ °áÇÕ ÇöóÁ Áú·®ºÐ¼®±â(Inductively Coupled Plasma Mass Spectrometer (ICP-MS))
Á¦ÀÛ»ç
PerkinElmer
¸ðµ¨¸í
NexION-300D
¼³Ä¡Àå¼Ò
Á¦1½ÇÇ赿 318È£
Àåºñ¸í
°íÈ¿À² À̹Ì¡ ½Ã½ºÅÛ(Electron Multiplying Charge-Coupled Device (EMCCD))
Á¦ÀÛ»ç
Andor
¸ðµ¨¸í
iXon DU-897
¼³Ä¡Àå¼Ò
Á¦3°øÇаü 006È£
Àåºñ¸í
±Ø¹Ì±¤ °ËÃâ Ä«¸Þ¶ó(Intensified Charged Coupled Device (ICCD))
Á¦ÀÛ»ç
Princeton Instruments
¸ðµ¨¸í
PI-MAX4-1024i
¼³Ä¡Àå¼Ò
Á¦3°øÇаü 105È£
Àåºñ¸í
¼±Çü À̿ Ʈ·¦ Áú·®ºÐ¼®±â(Linear Ion Trap Mass Spectrometry)
Á¦ÀÛ»ç
Thermo Scientific
¸ðµ¨¸í
VELOS PRO
¼³Ä¡Àå¼Ò
Áö°î¿¬±¸µ¿ 232È£
Àåºñ¸í
Àü°è¹æ»çÇü Åõ°úÀüÀÚ Çö¹Ì°æ(Field Emission Transmission Electron Microscope (FE-TEM))
Á¦ÀÛ»ç
JEOL
¸ðµ¨¸í
JSM-7100F
¼³Ä¡Àå¼Ò
ö°­´ëÇпø 154-6È£
Àåºñ¸í
Àü°è¹æ»çÇü Åõ°úÀüÀÚ Çö¹Ì°æ(Field Emission Transmission Electron Microscope (FE-TEM))
Á¦ÀÛ»ç
JEOL
¸ðµ¨¸í
JEM-2100F
¼³Ä¡Àå¼Ò
ö°­´ëÇпø 161È£
Àåºñ¸í
Àü°è¹æ»çÇü Åõ°úÀüÀÚ Çö¹Ì°æ(Field Emission Transmission Electron Microscope (FE-TEM))
Á¦ÀÛ»ç
JEOL
¸ðµ¨¸í
JXA-8530F
¼³Ä¡Àå¼Ò
ö°­´ëÇпø 163È£
Àåºñ¸í
Àü°è¹æ»çÇü Åõ°úÀüÀÚ Çö¹Ì°æ(Field Emission Transmission Electron Microscope (FE-TEM))
Á¦ÀÛ»ç
JEOL
¸ðµ¨¸í
JEM-7900F
¼³Ä¡Àå¼Ò
ö°­´ëÇпø 163È£
Àåºñ¸í
¹ß±¤ºÐ±¤ºÐ¼®±â(Optical Emission Spectrometer)
Á¦ÀÛ»ç
OBLF gmbh
¸ðµ¨¸í
OBLF QSN 750
¼³Ä¡Àå¼Ò
ö°­´ëÇпø 171-3È£
Àåºñ¸í
Àü±âºÐ¹« ÀÌ¿ÂÀ̵¿µµ ºÐ¼® - Áú·® ºÐ¼®±â(Electrospray ionization Ion mobility - Mass spectrometry)
Á¦ÀÛ»ç
AGILENT
¸ðµ¨¸í
Agilent 6560
¼³Ä¡Àå¼Ò
È­Çаü 112È£
Àåºñ¸í
´ÙÁß°ËÃâ À¯µµ°áÇÕÇöóÁ Áú·®ºÐ¼®±â(Multi-Collector Inductively Coupled Plasma Mass Spectrometer (MC-ICP-MS))
Á¦ÀÛ»ç
Nu Instruments Ltd
¸ðµ¨¸í
Plasma 3
¼³Ä¡Àå¼Ò
ȯ°æ°øÇе¿ 105È£
Àåºñ¸í
À¯µµ °áÇÕ ÇöóÁ ºÐ±¤ºÐ¼®±â(Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES))
Á¦ÀÛ»ç
Thermo Scientific
¸ðµ¨¸í
iCAP 7400
¼³Ä¡Àå¼Ò
ȯ°æ°øÇе¿ 106È£
»ç¿ëÁ¤º¸
Àåºñ¿ÀÇ¿©ºÎ
¡Û
ÀÚÀ²»ç¿ë¿©ºÎ
X
»ç¿ë·á
(³»ºÎ)26,900¿ø / ¿ø¼Ò
ÀÚ»êÁ¤º¸
Ãëµæ±Ý¾×
\ 81,429,238
ÃëµæÀÏ
2010-08-05
ÂüÁ¶»çÇ×
÷ºÎÆÄÀÏ
URL
https://www.thermofisher.com/kr/ko/home/industrial/mass-spectrometry/inductively-coupled-plasma-mass-spectrometry-icp-ms.html
Ű¿öµå
ICP, ¾×ü½Ã·á, ÇöóÁ
XS
SM
MD
LG
77 Cheongam-ro, Nam-gu, Pohang, Gyeongbuk, Republic of Korea (37673)
+82-54-279-3653
Copyright ¨Ï All rights Reserved.
[Àӽà °³¹ß¿µ¿ª º¸±â] 216.73.217.130